Description
Mastervolt Isolation Transformer Mass Gi 7Kw
Mastervolt Isolation Transformers: Mass GI, IVET D, and IVET Heavy Duty
From shore power to onboard network, you need to be careful when introducing shore power onboard, especially when the yacht is made of aluminium or steel. An incorrectly configured system can result in electrolysis, which will slowly but surely corrode the metal components. It is also important to protect the engine, rudder, rudderstock, propeller, and thruster on composite yachts. A Mastervolt isolation transformer will help preserve your valuable boat and provide you with the security of a correctly earthed 230V system.
Select the right transformer for your system:
- Lightweight Mass GI Transformer
- Ultra-modern high-frequency electronic switch technology.
- Lightweight and compact.
- Integrated Soft Start function.
- Connect to power from 90–255V and from 45–65Hz.
- Units can be parallel coupled for higher capacity.
- Higher efficiency with limited heat development.
- IVET D Isolation Transformers
- High-quality toroidal transformer in robust casing, including circuit breaker.
- Standard Soft Start for the suppression of inrush current at shore connection.
- Multi-tap version for both 230V 50Hz and 120V 60Hz shore voltage.
- IVET Heavy Duty Series
- High-quality isolation transformers without casing for self-installation.
- Optional Soft Start in synthetic casing.
- Capacities of 25–22kW.
- Modern transformer technology: light, silent, reliable, and easy.
Mastervolt’s Mass GI offers the latest high-frequency switching technology as well as Soft Start for peak loads when connecting to the shore. Weighing a mere six kilograms, LED lights on the casing indicate load and overload. The transformer can be remote-controlled via a panel and has the option of automatically starting the generator when there is a shore current overload.
Higher Capacity via Parallel Switching
Parallel switching of the Mass GI units increases the shore power capacity. Two 16A (3.5kW) units ensure 32A (7kW); four units give 64A (14kW).
Global Solution
The IVET D multi-tap is suitable for 230V (50Hz) and 120V (60Hz) American or Caribbean.
Install Anywhere
With its maritime aluminium casing, this isolation transformer can be fitted in any position on a wall or floor. No rubber mountings are necessary because the unit does not vibrate or hum. The Mass GI also features professional connections with strain relief cable glands.
Practical Tips
- Determine shore and onboard current: 230V, 120V, or both.
- Determine the capacity: maximum load with onboard power usage (amount of amps and kW).
- Note sizes and weight: the Mass GI is 75% lighter and 60% smaller compared to low-frequency transformers.
- Remember: The detection system for IVET Heavy Duty automatically supplies the onboard system with 230V in case of a 120V (60Hz) shore connection or vice versa.
- Use Systemswitch or Masterswitch for integrating shore power, generator, and/or inverter. Connects to 12V or 24V system battery charger or Mass Combi.
Specification | SKU 111260 | SKU 111262 |
---|---|---|
Mass GI | 3.5 | 7 |
Input | ||
Input Voltage | 90–255V | 90–255V |
Input Frequency | 45–65Hz | 45–65Hz |
Nominal Input Current at 230V | 16A | 32A |
No Load Consumption | 22W | 44W |
Earth Leakage Protection | No | No |
Output | ||
Output Voltage | 90–255V, ± 5% | 90–255V, ± 5% |
Output Frequency | 45–65Hz | 45–65Hz |
Soft Start | Yes | Yes |
Switch Off Behaviour | Breaker B-characteristic | Breaker B-characteristic |
Efficiency | >93% | >93% |
General Specifications | ||
Power | 3500 W* | 7000 W |
Technology | High frequency | High frequency |
Dimensions (HxWxD) mm | 340 x 261 x 144 | 340 x 261 x 250 |
Weight (kg) | 6 | 10 |
Ambient Temperature | 0–40°C, derating with 5% per °C (40–60°C) / 32–104°F, derating with 5% per °F (104–140°F) | 0–40°C, derating with 5% per °C (40–60°C) / 32–104°F, derating with 5% per °F (104–140°F) |
Switch Off at | 80°C / 176°F | 80°C / 176°F |
Cooling | Variofan | Variofan |
Operating Humidity | Max. 95% | Max. 95% |
Protection Degree | IP23 | IP23 |
MasterBus Compatible | Yes | Yes |
*Up to 4 units in parallel (14kW).
Voltage: 90-255V Power W: 7000 Max. Input current: 32A at 230V Dimensions HxWxD mm: 340x261x250 Weight: 10